5 the orientation of the vapor barrier depends on the home s location and climate.
Floor insulation water barrier section.
Seal rigid foam panels between foundation joists using spray foam.
The code requirement section r703 2 includes a qualification.
Breaks or joints in the air barrier should be sealed.
When warm moist air from the living space reaches the colder metal of the van walls it condenses into water and gets trapped potentially causing rust and other problems over time.
2 u factors can be met by cavity insulation alone or with continuous insulation alone or with both cavity and continuous insulation that results in a u factor.
To keep this from happening you need to install a vapor barrier between the insulation and your living space so that moisture can t even get to the metal walls.
So any plastic under the insulation will encourage moisture.
The best option under a concrete slab is foamular 250 which delivers r 5 per inch of thickness along with 25 psi of compressive strength.
So this is clearly an ineffective solution.
The code requirement calling for walls to be covered with number 15 asphalt felt is very odd because every manufacturer of asphalt felt declares unequivocally.
Vapor barriers are sheets of plastic or other material placed on one side of insulation sheets.
Use insulation hangers wire staves spaced every 12 to 18 inches to hold the floor insulation in place without compressing it more than 1 inch.
Usually composed of a thin film such as polyethylene vapor barriers are used to retard or prevent water vapor diffusion into a wall ceiling or floor during the cold winter.
Vapor barriers applied over the face of the insulation provide additional benefits in the fight against moisture.
Foam boards insulate while providing a partial vapor barrier.
Around objects that store or distribute hot water and indoor air.
2015 irc iecc air barrier and insulation installation table r402 4 1 1 n1102 4 1 1.
Pipe insulation duct insulation and water heater jackets.
Insulates ducts that pass through cold attics.
In most parts of the country the vapor barrier should face upward.
Up against the floor.
In any case the vapor barrier must point to the warm side.
Continuous air barrier 2 confirm that construction documents specify a continuous air barrier for the building components associated with the insulation of the exterior floor s.
You could put batts too.
For alternative construction assemblies see section 150 1 c 1a b and c.
Reflectix and similar reflective radiant barrier products provide almost no insulation under or on top of a concrete slag just r 1 for reflectix.
Vapor barrier goes on the warm in winter side.