Dead load weight of structure and fixed loads 10 lbs ft 2.
Flooring deflection 2x6.
Note it gives the allowable deflection based on a fractional span quantity so a larger denominator will yield less deflection.
1 psf lb f ft 2 47 88 n m 2.
If there is any deflection in the subfloor when walked on it would be advisable to add an additional layer of 3 8 or 1 2 thick plywood underlayment glued and screwed down over osb subfloor to add stability or install 2x6 blocking between the floor joists for added stability.
Check your code and.
For example the allowable deflection of a 12ft span floor joist with plaster l 360 is 0 4 12ft divided by 360.
This calculator is designed to work with dimensional lumber only.
The dead load on a floor is determined by the materials used in the floor s construction.
2 grade of douglas fir are indicated below.
So consider a simple gable roof on a 24 foot wide ranch framed with 2x6 exterior walls and a 1 1 2 ridge.
Ft plus any long term deflection due to the weight of the floor.
Live load psf dead load psf span calculator for wood joists and rafters available for the iphone.
The span would be 11 5 3 4.
Divide the total span of the floor joists in inches by 360 to determine the maximum amount the floor can give in the middle under a live load of 40 lb sq.
Ceiling joists are sized like floor joists except that deflection limits vary depending on whether the joists will be used for attic storage or will have a plaster or drywall finish.
Boss hog has instructed us that the feel of a floor depends on its resonant frequency as well as the the actual deflection.
By doubling up the joists we cut their deflection the distance they would bend under weight in half.
If there s wall board covered ceiling suspended from the underside of that floor the dead load increases to about 10 pounds per square foot.
Live load is weight of furniture wind snow and more.
If you have engineered truss or i beam type joists please do not use this calculator.
1 ft 0 3048 m.
Span calculator for wood joists and rafters also available for the android os.
If that same joist had gypsum ceiling l 240 the allowable deflection is 0 6.
Spacing in exterior exposure.
Maximum floor joist span for no.
Working in the unfinished basement below the bouncy floor we had to remove the plumbing and electrical lines running through the joists and then rerun the lines after the new 2x10s were in place.
See the table below.
For example the maximum deflection for a joist span of 15 is 15 12 360 1 2.
It was a complex expensive job.